{"product_id":"battery-chargers-ac-to-dc-chargers-victron-skylla-i-24v-100a-ac-to-dc-battery-charger","title":"Victron Skylla-i 24V 100A AC to DC battery charger (1+1) 230V","description":"\u003ch3\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eA MODERN AND POWERFUL BATTERY CHARGER\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eThe Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4A and with a slightly lower output voltage, is intended to top up a starter battery. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cu\u003e\u003cstrong\u003eRUGGED\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eAluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eCircuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.  \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cu\u003e\u003cstrong\u003eFLEXIBLE\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eNext to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to adapt the charge algorithm to a particular battery and its conditions of use. Please refer to the manual for a complete overview of the possibilities. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cu\u003e\u003cb\u003eFEATURES\u003c\/b\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eSynchronised parallel operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eSeveral chargers can be synchronised with the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables. Note: Two output and three output chargers cannot be paralleled with each other. Please see the manual for details.  \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eThe right amount of charge for a lead-acid battery\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003evariable absorption time When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003ePreventing damage due to excessive gassing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003ethe BatterySafe mode If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eLess maintenance and aging when the battery is not in use: the Storage mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V\/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.  \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eTo increase battery life: temperature compensation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eEvery Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and\/or when important fluctuations of battery temperature are expected. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eBattery voltage sense\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eIn order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage sense facility so that the battery always receives the correct charge voltage.\u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eSuitable for AC and DC supply (AC-DC and DC-DC operation) \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe chargers also accept a DC supply.  \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eUse as a power supply \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eAs a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries or large buffer capacitors are not available.  \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cstrong\u003eLi-Ion (LiFePO4) ready\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eSimple charger on-off control can be implemented by connecting a relay or open collector optocoupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the galvanically isolated CAN bus port. \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"color:#c0392b;\"\u003e\u003cu\u003e\u003cstrong\u003eWHATS IN THE BOX\u003c\/strong\u003e\u003c\/u\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e1 x Victron Skylla-i 24V 100A AC to DC battery charger (1+1) 230V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":43852758286403,"sku":"SDTG2401001","price":2085.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/1926\/2275\/files\/SDTG2401001.jpg?v=1789721369","url":"https:\/\/www.offroadliving.com.au\/products\/battery-chargers-ac-to-dc-chargers-victron-skylla-i-24v-100a-ac-to-dc-battery-charger","provider":"Offroad Living","version":"1.0","type":"link"}