Skip to product information
Frequently Bought Together:
200Ah Slimline Lithium battery with Bluetooth 12V AllSpark
SKU CODE: AS-12200SLIMBT
$2,299.00
Sale price
$2,299.00
Regular price
$0.00
Description
SERIOUS POWER, SERIOUS CONTROL, SERIOUS ADVENTURES
The AllSpark 12V 200Ah slimline lithium battery is built for adventurers who stay out longer - extended trips, serious free camping and week-plus getaways where running out of power isn't an option.
Built with brand-new A-Grade prismatic cells (not recycled or second-hand cells often found in cheaper batteries), a 200A continuous discharge and Bluetooth monitoring included as standard.it fits the tight spaces standard batteries can't — without compromising on the capacity that longer trips demand.
IEC 62619 certified. 7-year warranty. Designed and developed in Australia by Offroad Living.
Warranty
Features
Specifications
| SKU | AS-10012LTUSBT | AS-12100SLIMBT | AS-12150SLIMBT | AS-12200SLIMBT | AS-30012LISLBT | AS-30012LIUSLBT |
| Battery Level Specifications | ||||||
| Capacity Amp Hours (C5) | 100 | 150 | 200 | 300 | ||
| Watt Hours | 1,280 | 1,920 | 2,560 | 3,840 | ||
| Rated Voltage (V) | 12.8 | |||||
| Max Charge Voltage (V) | 14.6 | |||||
| Recommended Float Voltage (V) | 13.6 | |||||
| Low Voltage Cutoff (V) | 10 | |||||
| Rapid Charge Current (1C) for 30 mins (A) | 100 | 150 | 200 | 300 | ||
| Recommended Charge Current (A)* | 30–50 | 50 | 100 | |||
| Charge Profile | CC/CV | |||||
| Max Inverter Size (W — per single battery) | 2,500 | 3,000 | ||||
| Max Continuous Discharge (A) | 200 | 300 | ||||
| Peak Discharge — 5 secs (A) | 500 | 600 | ||||
| Charge Cycles¹ (residual capacity ≥85%) @ 80% Depth of Discharge @ 60% Depth of Discharge @ 40% Depth of Discharge |
> 3,200+¹ > 4,200+ > 5,000+ |
|||||
| Optimum Charge Temperature (°C) | < 45 | |||||
| Operating Temperature Range (°C) | -20 to +60 | |||||
| Storage Temperature Range (°C) | -40 to +125 | |||||
| Max Series Voltage (V) | 24 | |||||
| Max Batteries in Parallel | Unlimited | |||||
| Dimensions incl. Handles (mm) | 635 x 60 x 260 | 400 x 120 x 200 | 400 x 120 x 250 | 400 x 120 x 300 | 400 x 160 x 300 | 767 x 112 x 260 |
| Case Material | Ultraslim Aluminium | Slimline Aluminium | Ultraslim Aluminium | |||
| Weight (kg) | 13 | 12 | 18 | 21 | 31 | 31 |
| IP Rating | NOT WATERPROOF — INTERNAL USE ONLY | |||||
| Cell Level Specification | ||||||
| Cell Type | Prismatic | |||||
| Cell Connection | 4S1P | |||||
| Cell Capacity | 3.2V @ 100Ah | |||||
| Cell Casing | Nickel Plated Steel | |||||
| Cell Balancing Target (V) | 3.65 ± 0.025 | |||||
| Cell Balance Current (mA) | 35 ± 5 | |||||
| Cell Over Discharge LV Protection (V) | 2.5 ± 0.025 | |||||
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ | |||||
| Over Charge Cutoff (V) | 3.75 ± 0.025 | |||||
| Over Charge Detection Delay (secs) | 1–1.6 | |||||
| Over Charge Release (V) | 3.6 ± 0.0625 | |||||
| Over Charge Release | Auto Below Release Voltage | |||||
| Over Current Detection (1) (A) | 220 | |||||
| Over Current Detection Delay (1) (secs) | 10 | |||||
| Over Current Detection (2) (A) | 500 | |||||
| Over Current Detection Delay (2) (secs) | 5 | |||||
| Over Current Release | Remove Load — Auto Release | |||||
| Short Circuit Protection | External Short | |||||
| Short Circuit Detection Delay (μS) | 200–400 | |||||
| Short Circuit Recovery | Remove Load — Auto Release | |||||
| Internal Resistance (MOSFET Protection) | ≤20mΩ | |||||
Notes* Recommended charge current for best cell longevity. ¹ Cycle life independently laboratory tested at 0.2C₅ discharge rate and 0.2C charge rate up to 5,000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show residual capacity in excess of 85% of nameplate C5 capacity after 3,000 cycles. In real-world conditions, users will experience a range of temperature, current and voltage conditions which may affect actual battery performance over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.
SKUAS-10012LTUSBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 100 |
| Watt Hours | 1,280 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 100 |
| Recommended Charge Current (A)* | 30–50 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 2,500 |
| Max Continuous Discharge (A) | 200 |
| Peak Discharge — 5 secs (A) | 500 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 635 x 60 x 260 |
| Case Material | Ultraslim Aluminium |
| Weight (kg) | 13 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
SKUAS-12100SLIMBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 100 |
| Watt Hours | 1,280 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 100 |
| Recommended Charge Current (A)* | 30–50 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 2,500 |
| Max Continuous Discharge (A) | 200 |
| Peak Discharge — 5 secs (A) | 500 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 400 x 120 x 200 |
| Case Material | Slimline Aluminium |
| Weight (kg) | 12 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
SKUAS-12150SLIMBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 150 |
| Watt Hours | 1,920 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 150 |
| Recommended Charge Current (A)* | 30–50 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 2,500 |
| Max Continuous Discharge (A) | 200 |
| Peak Discharge — 5 secs (A) | 500 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 400 x 120 x 250 |
| Case Material | Slimline Aluminium |
| Weight (kg) | 18 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
SKUAS-12200SLIMBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 200 |
| Watt Hours | 2,560 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 200 |
| Recommended Charge Current (A)* | 50 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 2,500 |
| Max Continuous Discharge (A) | 200 |
| Peak Discharge — 5 secs (A) | 500 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 400 x 120 x 300 |
| Case Material | Slimline Aluminium |
| Weight (kg) | 21 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
SKUAS-30012LISLBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 300 |
| Watt Hours | 3,840 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 300 |
| Recommended Charge Current (A)* | 100 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 3,000 |
| Max Continuous Discharge (A) | 300 |
| Peak Discharge — 5 secs (A) | 600 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 400 x 160 x 300 |
| Case Material | Slimline Aluminium |
| Weight (kg) | 31 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
SKUAS-30012LIUSLBT
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 300 |
| Watt Hours | 3,840 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) 30 mins (A) | 300 |
| Recommended Charge Current (A)* | 100 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 3,000 |
| Max Continuous Discharge (A) | 300 |
| Peak Discharge — 5 secs (A) | 600 |
| Charge Cycles¹ ≥85% capacity @ 80% DoD | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | -20 to +60 |
| Storage Temp Range (°C) | -40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Dimensions incl. Handles (mm) | 767 x 112 x 260 |
| Case Material | Ultraslim Aluminium |
| Weight (kg) | 31 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target (V) | 3.65 ± 0.025 |
| Cell Balance Current (mA) | 35 ± 5 |
| Over Discharge LV Protection (V) | 2.5 ± 0.025 |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ± 0.025 |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ± 0.0625 |
| Over Charge Release | Auto Below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (μS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
⚠ Not waterproof — internal use only
Notes* Recommended charge current for best cell longevity. ¹ Cycle life independently laboratory tested at 0.2C₅ discharge rate and 0.2C charge rate up to 5,000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show residual capacity in excess of 85% of nameplate C5 capacity after 3,000 cycles. In real-world conditions, users will experience a range of temperature, current and voltage conditions which may affect actual battery performance over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.
SKUAS-12200SLIMBT
| Battery Level | |
| Capacity (C5) | 200Ah |
| Watt Hours | 2,560Wh |
| Rated Voltage | 12.8V |
| Max Charge Voltage | 14.6V |
| Float Voltage | 13.6V |
| Low Voltage Cutoff | 10V |
| Rapid Charge (1C / 30 min) | 100A |
| Recommended Charge* | 50A |
| Charge Profile | CC/CV |
| Max Inverter Size | 2,500W |
| Max Continuous Discharge | 200A |
| Peak Discharge (5 sec) | 500A |
| Cycle Life @ 80% DoD | >3,200+ |
| Cycle Life @ 60% DoD | >4,200+ |
| Cycle Life @ 40% DoD | >5,000+ |
| Optimum Charge Temp | <45°C |
| Operating Temp Range | −20 to +60°C |
| Storage Temp Range | −40 to +125°C |
| Max Series Voltage | 24V |
| Max Parallel | Unlimited |
| Physical | |
| Dimensions (mm) | 400 × 120 × 300 |
| Case Material | Slimline Aluminium |
| Weight | 21 kg |
| Cell Level | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balance Target | 3.65 ±0.025V |
| Balance Current | 35 ±5 mA |
| OD LV Protection | 2.5 ±0.025V |
| OD Release | 10.5V+ & 1A+ |
| OC Cutoff | 3.75 ±0.025V |
| OC Detection Delay | 1–1.6 secs |
| OC Release | 3.6 ±0.0625V |
| Over Current (1) | 220A / 10 sec |
| Over Current (2) | 500A / 5 sec |
| SC Detection Delay | 200–400 μs |
| Internal Resistance | ≤20mΩ |
⚠ Not Waterproof — Internal Use Only
Notes* Recommended charge current is for best cell longevity. Independently laboratory tested at 0.2C₅ / 0.2C, 25°C. Residual capacity >85% after 3,000 cycles. High current & temperature extremes will reduce cycle life.
Downloads
FAQS