Cable Size & Circuit Protection Calculator
Undersized cable is one of the most common mistakes in 12V, 24V and 48V DC systems - and one of the most dangerous. Too-thin cable causes excessive voltage drop, wasted power, and heat build-up that can damage equipment or create a fire risk. Use this calculator to find the cable size and fuse rating we would recommend for your setup.
Â
Select from Inverter or DC load (use for Solar also), enter your voltage, load and cable run length, and the calculator will recommend a cable size that keeps voltage drop within safe limits while ensuring your circuit protection is correctly matched.
Â
If you need more information on how to use this calculator, check out the full article on Cable & Circuit Protection Sizing over here.Â
Â
Load type
Continuous watt rating of your inverter
Continuous current draw of the DC load
One way — voltage drop uses round trip (2×)
3% recommended for most installs
NB. When calculating DC-DC charger input cable sizes, increase input load current by 10% compared to output charge current.
Max current
—
—
Recommended fuse
—
Next standard size above max current
Recommended cable
—
—
Cable comparison
Showing recommended cable plus 2 sizes smaller and 2 larger. Voltage drop calculated at max current. Ampacity checked against fuse size (the fuse protects the cable).
| Cable | Area (mm²) | Rated amps | Est. V drop | Est. % drop | Passes |
|---|