Frequently Bought Together:
200Ah Lithium Battery 12V Bluetooth Waterproof Chassis Mount AllSpark ( IP67)
Description
THE ALLSPARK 200AH CHASSIS MOUNT - SERIOUS OFF-GRID POWER WITHOUT LOSING YOUR STORAGE SPACE
The AllSpark 200Ah 12V is a purpose-built caravan lithium battery box that mounts directly to your chassis - freeing up your under-bed storage, meeting compliance requirements, and delivering serious off-grid power without compromise.
Designed and developed in Australia by Offroad Living, it's IP67 sealed, IEC 62619 certified as a complete battery unit, and built from powder-coated stainless steel to handle corrugated outback roads, creek crossings, and 40°C summer heat. Bluetooth monitoring is included at no extra cost, so you can check your exact state of charge, individual cell voltages, and full charge history - right from your phone.
If you want a sealed lithium battery box for your caravan that keeps your internal storage intact and your compliance worries off the table, the AllSpark 200Ah delivers.
Warranty
Features
Specifications
| SKU | AS-20012LICMBT | AS-30012LICMBT | AS-40012LICMBT | AS-20024LICMBT | AS-10048BATLI200500CM |
| Battery Level Specifications | |||||
| Capacity Amp Hours (C5) | 200 | 300 | 400 | 200 | 100 |
| Watt Hours | 2560 | 3840 | 5120 | ||
| Rated Voltage (V) | 12.8 | 25.6 | 51.2 | ||
| Max Charge Voltage (V) | 14.6 | 29.2 | 58.4 | ||
| Recommended Float Voltage (V) | 13.6 | 27.2 | 54.4 | ||
| Low Voltage Cutoff (V) | 10 | 20 | 40 | ||
| Rapid Charge Current (1C) for 30 mins (A) | 200 | 300 | 400 | 200 | 100 |
| Recommended Charge Current (A)* | 50–80 | 50–120 | 80–150 | 50–80 | 30–50 |
| Charge Profile | CC/CV | ||||
| Max Inverter Size (W — per single battery) | 2500 | 3000 | 4000 | 5000 | |
| Max Continuous Discharge (A) | 200 | 300 | 200 | 200 | |
| Peak Discharge — 10 secs (A) | 500 | 600 | 500 | 500 | |
| Charge Cycles @ 80% DoD# (≥85% residual capacity) @ 60% DoD @ 40% DoD | > 3200+# > 4200+ > 5000+ | ||||
| Optimum Charge Temperature (˚C) | < 45 | ||||
| Operating Temperature Range (˚C) | −20 to +60 | ||||
| Storage Temperature Range (˚C) | −40 to +125 | ||||
| Max Series Voltage | Parallel connection only — series not permitted | ||||
| Max Batteries in Parallel | 4 | ||||
| Dimensions incl. Mounts (mm) | 350 × 300 × 200 | 400 × 300 × 200 | 550 × 300 × 200 | ||
| Case Material | Powder coated stainless steel — with threaded vent pipe fitting and cap | ||||
| Terminals | 2 × M8 Bolted Terminals (1 × Red Positive, 1 × Black Negative) | ||||
| Weight (kg) | 25 | 36.5 | 51.3 | ||
| IP Rating | IP67 | ||||
| Cell Level Specification | |||||
| Cell Type | Prismatic | ||||
| Cell Connection | 4S1P | 4S2P | 8S1P | 16S1P | |
| Cell Capacity | 3.2V @ 200Ah | 3.2V @ 300Ah | 3.2V @ 200Ah | 3.2V @ 100Ah | |
| Cell Casing | Nickel plated steel | ||||
| Cell Balancing Target (V) | 3.65 ±0.025 | ||||
| Cell Balance Current (mA) | 35 ±5 | ||||
| Cell Over Discharge LV Protection (V) | 2.5 ±0.025 | ||||
| Over Discharge Release | Apply charge 10.5V+ & 1A+ | ||||
| Over Charge Cutoff (V) | 3.75 ±0.025 | 3.65 ±0.025 | 3.75 ±0.025 | 3.65 ±0.025 | |
| Over Charge Detection Delay (secs) | 1–1.6 | ||||
| Over Charge Release (V) | 3.6 ±0.0625 | ||||
| Over Charge Release Method | Auto below release voltage | ||||
| Over Current Detection (1) (A) | 220 | 330 | 220 | ||
| Over Current Detection Delay (1) (secs) | 10 | ||||
| Over Current Detection (2) (A) | 500 | 600 | 500 | ||
| Over Current Detection Delay (2) (secs) | 5 | ||||
| Over Current Release | Remove load — auto release | ||||
| Short Circuit Protection | External short | ||||
| Short Circuit Detection Delay (µS) | 200–400 | ||||
| Short Circuit Recovery | Remove load — auto release | ||||
| Internal Resistance (MOSFET Protection) | ≤20mΩ | ||||
| Battery Level Specifications | |
| Capacity (C5) | 200Ah |
| Watt Hours | 2560Wh |
| Rated Voltage | 12.8V |
| Max Charge Voltage | 14.6V |
| Recommended Float | 13.6V |
| Low Voltage Cutoff | 10V |
| Rapid Charge (1C/30min) | 200A |
| Recommended Charge* | 50–80A |
| Charge Profile | CC/CV |
| Max Inverter Size | 2500W |
| Max Continuous Discharge | 200A |
| Peak Discharge (10s) | 500A |
| Cycles @ 80% DoD# | > 3200+ |
| Cycles @ 60% DoD | > 4200+ |
| Cycles @ 40% DoD | > 5000+ |
| Optimum Charge Temp | < 45˚C |
| Operating Temp Range | −20 to +60˚C |
| Storage Temp Range | −40 to +125˚C |
| Max Series Voltage | Parallel only |
| Max Batteries in Parallel | 4 |
| Dimensions incl. Handles | 350 × 300 × 200mm |
| Case Material | Powder coated stainless steel |
| Terminals | 2 × M8 Bolted |
| Weight | 25kg |
| IP Rating | IP67 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 200Ah |
| Cell Casing | Nickel plated steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current | 35 ±5mA |
| OD LV Protection | 2.5 ±0.025V |
| Over Discharge Release | Apply 10.5V+ & 1A+ |
| Over Charge Cutoff | 3.75 ±0.025V |
| OC Detection Delay | 1–1.6s |
| Over Charge Release | 3.6 ±0.0625V |
| OC Release Method | Auto below release voltage |
| Over Current Det. (1) | 220A |
| OCD Delay (1) | 10s |
| Over Current Det. (2) | 500A |
| OCD Delay (2) | 5s |
| Over Current Release | Remove load — auto |
| Short Circuit Protection | External short |
| SC Detection Delay | 200–400µS |
| SC Recovery | Remove load — auto |
| Internal Resistance | ≤20mΩ |
| Battery Level Specifications | |
| Capacity (C5) | 300Ah |
| Watt Hours | 3840Wh |
| Rated Voltage | 12.8V |
| Max Charge Voltage | 14.6V |
| Recommended Float | 13.6V |
| Low Voltage Cutoff | 10V |
| Rapid Charge (1C/30min) | 300A |
| Recommended Charge* | 50–120A |
| Charge Profile | CC/CV |
| Max Inverter Size | 3000W |
| Max Continuous Discharge | 300A |
| Peak Discharge (10s) | 600A |
| Cycles @ 80% DoD# | > 3200+ |
| Cycles @ 60% DoD | > 4200+ |
| Cycles @ 40% DoD | > 5000+ |
| Optimum Charge Temp | < 45˚C |
| Operating Temp Range | −20 to +60˚C |
| Storage Temp Range | −40 to +125˚C |
| Max Series Voltage | Parallel only |
| Max Batteries in Parallel | 4 |
| Dimensions incl. Handles | 400 × 300 × 200mm |
| Case Material | Powder coated stainless steel |
| Terminals | 2 × M8 Bolted |
| Weight | 36.5kg |
| IP Rating | IP67 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 300Ah |
| Cell Casing | Nickel plated steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current | 35 ±5mA |
| OD LV Protection | 2.5 ±0.025V |
| Over Discharge Release | Apply 10.5V+ & 1A+ |
| Over Charge Cutoff | 3.75 ±0.025V |
| OC Detection Delay | 1–1.6s |
| Over Charge Release | 3.6 ±0.0625V |
| OC Release Method | Auto below release voltage |
| Over Current Det. (1) | 330A |
| OCD Delay (1) | 10s |
| Over Current Det. (2) | 600A |
| OCD Delay (2) | 5s |
| Over Current Release | Remove load — auto |
| Short Circuit Protection | External short |
| SC Detection Delay | 200–400µS |
| SC Recovery | Remove load — auto |
| Internal Resistance | ≤20mΩ |
| Battery Level Specifications | |
| Capacity (C5) | 400Ah |
| Watt Hours | 5120Wh |
| Rated Voltage | 12.8V |
| Max Charge Voltage | 14.6V |
| Recommended Float | 13.6V |
| Low Voltage Cutoff | 10V |
| Rapid Charge (1C/30min) | 400A |
| Recommended Charge* | 80–150A |
| Charge Profile | CC/CV |
| Max Inverter Size | 3000W |
| Max Continuous Discharge | 300A |
| Peak Discharge (10s) | 600A |
| Cycles @ 80% DoD# | > 3200+ |
| Cycles @ 60% DoD | > 4200+ |
| Cycles @ 40% DoD | > 5000+ |
| Optimum Charge Temp | < 45˚C |
| Operating Temp Range | −20 to +60˚C |
| Storage Temp Range | −40 to +125˚C |
| Max Series Voltage | Parallel only |
| Max Batteries in Parallel | 4 |
| Dimensions incl. Handles | 550 × 300 × 200mm |
| Case Material | Powder coated stainless steel |
| Terminals | 2 × M8 Bolted |
| Weight | 51.3kg |
| IP Rating | IP67 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S2P |
| Cell Capacity | 3.2V @ 200Ah |
| Cell Casing | Nickel plated steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current | 35 ±5mA |
| OD LV Protection | 2.5 ±0.025V |
| Over Discharge Release | Apply 10.5V+ & 1A+ |
| Over Charge Cutoff | 3.65 ±0.025V |
| OC Detection Delay | 1–1.6s |
| Over Charge Release | 3.6 ±0.0625V |
| OC Release Method | Auto below release voltage |
| Over Current Det. (1) | 330A |
| OCD Delay (1) | 10s |
| Over Current Det. (2) | 600A |
| OCD Delay (2) | 5s |
| Over Current Release | Remove load — auto |
| Short Circuit Protection | External short |
| SC Detection Delay | 200–400µS |
| SC Recovery | Remove load — auto |
| Internal Resistance | ≤20mΩ |
| Battery Level Specifications | |
| Capacity (C5) | 200Ah |
| Watt Hours | 5120Wh |
| Rated Voltage | 25.6V |
| Max Charge Voltage | 29.2V |
| Recommended Float | 27.2V |
| Low Voltage Cutoff | 20V |
| Rapid Charge (1C/30min) | 200A |
| Recommended Charge* | 50–80A |
| Charge Profile | CC/CV |
| Max Inverter Size | 4000W |
| Max Continuous Discharge | 200A |
| Peak Discharge (10s) | 500A |
| Cycles @ 80% DoD# | > 3200+ |
| Cycles @ 60% DoD | > 4200+ |
| Cycles @ 40% DoD | > 5000+ |
| Optimum Charge Temp | < 45˚C |
| Operating Temp Range | −20 to +60˚C |
| Storage Temp Range | −40 to +125˚C |
| Max Series Voltage | Parallel only |
| Max Batteries in Parallel | 4 |
| Dimensions incl. Handles | 550 × 300 × 200mm |
| Case Material | Powder coated stainless steel |
| Terminals | 2 × M8 Bolted |
| Weight | 51.3kg |
| IP Rating | IP67 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 8S1P |
| Cell Capacity | 3.2V @ 200Ah |
| Cell Casing | Nickel plated steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current | 35 ±5mA |
| OD LV Protection | 2.5 ±0.025V |
| Over Discharge Release | Apply 10.5V+ & 1A+ |
| Over Charge Cutoff | 3.75 ±0.025V |
| OC Detection Delay | 1–1.6s |
| Over Charge Release | 3.6 ±0.0625V |
| OC Release Method | Auto below release voltage |
| Over Current Det. (1) | 220A |
| OCD Delay (1) | 10s |
| Over Current Det. (2) | 500A |
| OCD Delay (2) | 5s |
| Over Current Release | Remove load — auto |
| Short Circuit Protection | External short |
| SC Detection Delay | 200–400µS |
| SC Recovery | Remove load — auto |
| Internal Resistance | ≤20mΩ |
| Battery Level Specifications | |
| Capacity (C5) | 100Ah |
| Watt Hours | 5120Wh |
| Rated Voltage | 51.2V |
| Max Charge Voltage | 58.4V |
| Recommended Float | 54.4V |
| Low Voltage Cutoff | 40V |
| Rapid Charge (1C/30min) | 100A |
| Recommended Charge* | 30–50A |
| Charge Profile | CC/CV |
| Max Inverter Size | 5000W |
| Max Continuous Discharge | 200A |
| Peak Discharge (10s) | 500A |
| Cycles @ 80% DoD# | > 3200+ |
| Cycles @ 60% DoD | > 4200+ |
| Cycles @ 40% DoD | > 5000+ |
| Optimum Charge Temp | < 45˚C |
| Operating Temp Range | −20 to +60˚C |
| Storage Temp Range | −40 to +125˚C |
| Max Series Voltage | Parallel only |
| Max Batteries in Parallel | 4 |
| Dimensions incl. Handles | 550 × 300 × 200mm |
| Case Material | Powder coated stainless steel |
| Terminals | 2 × M8 Bolted |
| Weight | 51.3kg |
| IP Rating | IP67 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 16S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel plated steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current | 35 ±5mA |
| OD LV Protection | 2.5 ±0.025V |
| Over Discharge Release | Apply 10.5V+ & 1A+ |
| Over Charge Cutoff | 3.65 ±0.025V |
| OC Detection Delay | 1–1.6s |
| Over Charge Release | 3.6 ±0.0625V |
| OC Release Method | Auto below release voltage |
| Over Current Det. (1) | 220A |
| OCD Delay (1) | 10s |
| Over Current Det. (2) | 500A |
| OCD Delay (2) | 5s |
| Over Current Release | Remove load — auto |
| Short Circuit Protection | External short |
| SC Detection Delay | 200–400µS |
| SC Recovery | Remove load — auto |
| Internal Resistance | ≤20mΩ |