Frequently Bought Together:
100ah Lithium Battery 12V AllSpark with Bluetooth IP65
Description
THE ALLSPARK 100AH LITHIUM BATTERY IS BUILT FOR AUSSIE CONDITIONS
Â
The 100Ah lithium battery 12V AllSpark with Bluetooth IP65 is built for serious off-grid touring in Australian conditions. If you’re chasing a dependable lithium battery 100Ah that can handle corrugations, heat and real camping loads without extra gear, this is it.
Â
With a exclusive solid state BMS, BRAND NEW* premium A-grade prismatic cells and built-in Bluetooth monitoring, you get accurate data straight from the battery -Â no external shunts, no added cost. Rated for 3200+ cycles at 80% DoD and backed by a 7-year warranty, this 12V 100Ah lithium battery is designed to outlast and outperform standard setups.
Â
Whether you’re running a fridge, lights or a 1000W inverter, this is a serious contender for the best 100Ah lithium battery Australia has to offer.
(* yes, it's true! Second hand cells are used in "new", cheap battery brands - this is why warranties are lower and inconsistency between batches can be significant)
Â
Warranty
Features
Specifications
| SKU | AS-12100PRIMEBT | AS-20012LIABSBT | AS-30012LIABSBT |
| Battery Level Specifications | |||
| Capacity Amp Hours (C5) | 100 | 200 | 300 |
| Watt Hours | 1,280 | 2,560 | 3,840 |
| Rated Voltage (V) | 12.8 | ||
| Max Charge Voltage (V) | 14.6 | ||
| Recommended Float Voltage (V) | 13.6 | ||
| Low Voltage Cutoff (V) | 10 | ||
| Rapid Charge Current (1C) for 30 mins (A) | 100 | 200 | 300 |
| Recommended Charge Current (A)* | 20–40 | 50–80 | 50–150 |
| Charge Profile | CC/CV | ||
| Max Inverter Size (W — per single battery) | 1,000 | 2,500 | 3,000 |
| Max Continuous Discharge (A) | 100 | 200 | 300 |
| Peak Discharge — 10 secs (A) | 200 | 500 | 600 |
| Charge Cycles @ 80% DoD# (residual capacity ≥85%) @ 60% DoD @ 40% DoD | > 3,200+# > 4,200+ > 5,000+ | ||
| Optimum Temperature During Charging (°C) | < 45 | ||
| Operating Temperature Range (°C) | −20 to +60 | ||
| Storage Temperature Range (°C) | −40 to +125 | ||
| Max Series Voltage (V) | 24 | ||
| Max Batteries in Parallel | Unlimited | ||
| Overall Dimensions incl. Handles (L Ă— W Ă— H mm) | 229 Ă— 138 Ă— 208 (+4mm for terminals) | 340 Ă— 190 Ă— 247 (+5mm for terminals) | 340 Ă— 190 Ă— 247 (+5mm for terminals) |
| Case Footprint Dimensions (L Ă— W Ă— H mm) | 224 Ă— 134 Ă— 208 | 340 Ă— 183 Ă— 247 | |
| Case Material | ABS Plastic | ||
| Weight (kg) | 9.5 | 21 | 26 |
| IP Rating | IP65 | ||
| Cell Level Specification | |||
| Cell Type | Prismatic | ||
| Cell Connection | 4S1P | ||
| Cell Capacity | 3.2V @ 100Ah | 3.2V @ 200Ah | 3.2V @ 300Ah |
| Cell Casing | Nickel Plated Steel | ||
| Cell Balancing Target | 3.65 ±0.025V | ||
| Cell Balance Current (mA) | 35 ±5 | ||
| Cell Over Discharge LV Protection (V) | 2.5 ±0.025V | ||
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ | ||
| Over Charge Cutoff (V) | 3.75 ±0.025V | ||
| Over Charge Detection Delay (secs) | 1–1.6 | ||
| Over Charge Release (V) | 3.6 ±0.0625V | ||
| Over Charge Release | Auto below Release Voltage | ||
| Over Current Detection (1) (A) | N/A | 220 | 330 |
| Over Current Detection Delay (1) (secs) | N/A | 10 | |
| Over Current Detection (2) (A) | 200 | 500 | |
| Over Current Detection Delay (2) (secs) | 10 | 5 | |
| Over Current Release | Remove Load — Auto Release | ||
| Short Circuit Protection | External Short | ||
| Short Circuit Detection Delay (µS) | 200–400 | ||
| Short Circuit Recovery | Remove Load — Auto Release | ||
| Internal Resistance (MOSFET Protection) | ≤20mΩ | ||
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 100 |
| Watt Hours | 1,280 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) for 30 mins (A) | 100 |
| Recommended Charge Current (A)* | 20–40 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 1,000 |
| Max Continuous Discharge (A) | 100 |
| Peak Discharge — 10 secs (A) | 200 |
| Charge Cycles @ 80% DoD# | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | −20 to +60 |
| Storage Temp Range (°C) | −40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Overall Dimensions incl. Handles (mm) | 229 Ă— 138 Ă— 208 (+4mm terminals) |
| Case Footprint (mm) | 224 Ă— 134 Ă— 208 |
| Case Material | ABS Plastic |
| Weight (kg) | 9.5 |
| IP Rating | IP65 |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 100Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current (mA) | 35 ±5 |
| Cell Over Discharge LV Protection (V) | 2.5 ±0.025V |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ±0.025V |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ±0.0625V |
| Over Charge Release | Auto below Release Voltage |
| Over Current Detection (1) (A) | N/A |
| Over Current Detection Delay (1) (secs) | N/A |
| Over Current Detection (2) (A) | 200 |
| Over Current Detection Delay (2) (secs) | 10 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (µS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 200 |
| Watt Hours | 2,560 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) for 30 mins (A) | 200 |
| Recommended Charge Current (A)* | 50–80 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 2,500 |
| Max Continuous Discharge (A) | 200 |
| Peak Discharge — 10 secs (A) | 500 |
| Charge Cycles @ 80% DoD# | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | −20 to +60 |
| Storage Temp Range (°C) | −40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Overall Dimensions incl. Handles (mm) | 340 Ă— 190 Ă— 247 (+5mm terminals) |
| Case Footprint (mm) | 340 Ă— 183 Ă— 247 |
| Case Material | ABS Plastic |
| Weight (kg) | 21 |
| IP Rating | — |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 200Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current (mA) | 35 ±5 |
| Cell Over Discharge LV Protection (V) | 2.5 ±0.025V |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ±0.025V |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ±0.0625V |
| Over Charge Release | Auto below Release Voltage |
| Over Current Detection (1) (A) | 220 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (µS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |
| Battery Level Specifications | |
| Capacity Amp Hours (C5) | 300 |
| Watt Hours | 3,840 |
| Rated Voltage (V) | 12.8 |
| Max Charge Voltage (V) | 14.6 |
| Recommended Float Voltage (V) | 13.6 |
| Low Voltage Cutoff (V) | 10 |
| Rapid Charge Current (1C) for 30 mins (A) | 300 |
| Recommended Charge Current (A)* | 50–150 |
| Charge Profile | CC/CV |
| Max Inverter Size (W) | 3,000 |
| Max Continuous Discharge (A) | 300 |
| Peak Discharge — 10 secs (A) | 600 |
| Charge Cycles @ 80% DoD# | > 3,200+ |
| Charge Cycles @ 60% DoD | > 4,200+ |
| Charge Cycles @ 40% DoD | > 5,000+ |
| Optimum Charge Temp (°C) | < 45 |
| Operating Temp Range (°C) | −20 to +60 |
| Storage Temp Range (°C) | −40 to +125 |
| Max Series Voltage (V) | 24 |
| Max Batteries in Parallel | Unlimited |
| Overall Dimensions incl. Handles (mm) | 340 Ă— 190 Ă— 247 (+5mm terminals) |
| Case Footprint (mm) | 340 Ă— 183 Ă— 247 |
| Case Material | ABS Plastic |
| Weight (kg) | — |
| IP Rating | — |
| Cell Level Specification | |
| Cell Type | Prismatic |
| Cell Connection | 4S1P |
| Cell Capacity | 3.2V @ 300Ah |
| Cell Casing | Nickel Plated Steel |
| Cell Balancing Target | 3.65 ±0.025V |
| Cell Balance Current (mA) | 35 ±5 |
| Cell Over Discharge LV Protection (V) | 2.5 ±0.025V |
| Over Discharge Release | Apply Charge 10.5V+ & 1A+ |
| Over Charge Cutoff (V) | 3.75 ±0.025V |
| Over Charge Detection Delay (secs) | 1–1.6 |
| Over Charge Release (V) | 3.6 ±0.0625V |
| Over Charge Release | Auto below Release Voltage |
| Over Current Detection (1) (A) | 330 |
| Over Current Detection Delay (1) (secs) | 10 |
| Over Current Detection (2) (A) | 500 |
| Over Current Detection Delay (2) (secs) | 5 |
| Over Current Release | Remove Load — Auto Release |
| Short Circuit Protection | External Short |
| Short Circuit Detection Delay (µS) | 200–400 |
| Short Circuit Recovery | Remove Load — Auto Release |
| Internal Resistance (MOSFET) | ≤20mΩ |