Portable Power Station | AllSpark 'The Grid' 300ah | with 2500W Inverter

Portable Power Station | AllSpark 'The Grid' 300ah | with 2500W Inverter

$5,499.00
Sale price  $5,499.00 Regular price  $6,479.00
Skip to product information
Sale
Portable Power Station | AllSpark 'The Grid' 300ah | with 2500W Inverter

Portable Power Station | AllSpark 'The Grid' 300ah | with 2500W Inverter

SKU CODE: AS-GRID300INV2500
$5,499.00
Sale price  $5,499.00 Regular price  $6,479.00 Save 15%!

Description

MEET "THE GRID" BY ALLSPARK - YOUR GO-TO ULTIMATE PORTABLE POWER STATION FOR SERIOUS CAMPERS

Boasting a whopping 300Ah of AllSpark Bluetooth battery capcacity with a high current rate to power the AllSpark Pro Series 2500W Inverter, you can kiss power woes goodbye. Paired with the in-built Redarc 50A Alpha BCDC charger, experience reliable, rapid plug and play charging, and rest easy knowing your devices are always fueled for action.

"The Grid" by AllSpark: Because when you're on the go, power should never be an afterthought.

Includes:

  • AllSpark 300ah Bluetooth LiFePO4 battery - with a 7 YEAR WARRANTY
  • AllSpark 2500W Pro Series Inverter - 3 YEAR WARRANTY
  • Redarc Alpha 50A BCDC charger with 60A resetable AllSpark Circuit Breaker
  • 50A anderson plugs for alternator and solar inputs to BCDC
  • 2 x 50A plugs for input/output power with 60A resetable circuit breaker
  • Cig + Dual Port QC 3.0 USB A + PD65 USB Type C with 15A resetable circuit breaker protection
  • Posifit fridge socket with 15A resetable circuit protection
  • 200A circuit breaker and terminals to connect the included AllSpark 2000w inverter

AllSpark 300Ah Bluetooth Lithium Battery: Unleash the power of lithium with the Allspark 300Ah Bluetooth Lithium Battery. This high-performance next generation solid state battery offers a constant output of 200 Amps and a peak output of 500A, ensuring you have the energy you need when you need it. Lightweight, compact, and with a longer lifespan than any other batteries, the Allspark Lithium Battery is your ticket to a reliable and efficient power source.

Check out the AllSpark 300ah ABS Bluetooth Lithium Battery here

AllSpark 2500W Pro Series Inverter: This Inverter has 2500W of continuous power and a 5000W surge.

Check out the AllSpark 2500W Pro Series Inverter here

RedArc Alpha 50 BCDC charger:

Ensure you're never left powerless on your journeys with the REDARC BCDC ALPHA50 Battery Charger. Designed for rugged conditions, this charger delivers consistent, efficient charging to keep your batteries at peak performance, whether you're navigating remote trails or camping off-grid. Crafted in Australia, the BCDC ALPHA50 is your steadfast companion in off-road adventures. Its advanced design harnesses power from both your vehicle’s alternator and solar panels to charge auxiliary and start batteries efficiently

Check out the RedArc Alpha 50 here

We've done all the hard work for you - Normal retail price to purchase all components would be $6352. Fully wired and ready to go in a discounted bundle package.

SPECIAL NOTE: AllSpark "The Grid" is a made to order product by Offroad Living in our Wangara workshop. Please allow up to 2-4 weeks for each production run for your order to be made.

WHATS IN THE BOX*

  • 1 x "The Grid" Portable Power Station by AllSpark, including:
    • 1 x 300Ah AllSpark Lithium Battery
    • 1 x 2500W AllSpark Pro Series Inverter
    • 1 x Redarc Alpha 50 BCDC Charger
    • Circuit protection
    • Sockets/Inputs
    • Includes mounting tray and tie down straps

*** PLEASE NOTE: Your AllSpark LiFePO4 battery will come isolated at the time of delivery. You must download the AllSpark App, connect to the batttery and turn on both the "Charge" and "Discharge" buttons to activate the battery ***

Features

  • Advanced cell technology with compact cells and casing
  • Exclusive Solid state BMS designed and developed by Offroad Living
  • Highest quality premium grade prismatic cells - resistance matched, long battery life and no voltage sag with a 20 year design life
  • Greater than 3000 cycles @ 80% DoD before reaching 85% of original capacity
  • Pro Series Inverter with 2000W continuous output (4000W surge)
  • RedArc Alpha 50 comes with Green Solar Priority - it will select solar charging first in an effort to reduce the load on your alternator 
  •  50A anderson plugs for alternator and solar inputs to BCDC
  •  2 x 50A plugs for input/output power with 60A resetable circuit breaker
  • Switch for Cig & Dual Port QC 3.0 USB A + PD65 USB Type C with 15A resetable circuit breaker protection 
  • Switch for Fridge Engel/Posifit socket with 15A resetable circuit protection
  • 200A CB to connect the 2000w inverter 

Specifications

SKUAS-GRID200AS-GRID200INVAS-GRID300AS-GRID300INVAS-GRID300INV2500
The Grid — System Overview
Battery200Ah AllSpark BT ABS Lithium (AS-20012LIABSBT)300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
Inverter—AllSpark 12V 2000W Pro-Series—AllSpark 12V 2000W Pro-SeriesAllSpark 12V 2500W Pro-Series
Dimensions — Base Unit (L×W×H mm)540 × 207 × 287
Dimensions — Inc. Inverter (L×W×H mm)N/A540 × 220 × 383N/A540 × 220 × 383540 × 220 × 383
Weight — Base Unit (kg)26.533.9
Weight — Inc. Inverter (kg)N/A31.1N/A35.736.5
AllSpark ABS Lithium Battery — Battery Level Specifications
Capacity Amp Hours (C5)200300
Watt Hours2,5603,840
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge Current (1C) for 30 mins200300
Recommended Charge Current (A)*50–8050–150
Charge ProfileCC/CV
Max Inverter Size (W — per single battery)25003000
Max Continuous Discharge (A)200300
Peak Discharge — 10 secs (A)500600
Charge Cycles @ 80% DoD# (≥85% residual capacity)
@ 60% DoD
@ 40% DoD
> 3200+#
> 4200+
> 5000+
Optimum Temperature During Charging (˚C)< 45
Operating Temperature Range (˚C)−20 to +60
Storage Temperature Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles (L×W×H mm)367 × 190 × 247 (+5mm for terminals)
Case Footprint Dimensions (L×W×H mm)340 × 183 × 247
Case MaterialABS Plastic
Weight (kg)2131
AllSpark ABS Lithium Battery — Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 200Ah3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell Over Discharge LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
Over Charge Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)220330
Over Current Detection Delay (1) (Secs)10
Over Current Detection (2) (A)500
Over Current Detection Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
Short Circuit Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET Protection)≤20mΩ
AllSpark 12V Pro-Series Inverter (2000W / 2500W)
Model—12V 2000W—12V 2000W12V 2500W
Input Voltage—12V—12V12V
Input Voltage Range—9.6–15VDC—9.6–15VDC9.6–15VDC
Idle Current—0.8A—0.8A0.8A
Efficiency—>90%—>90%>90%
Input Connector—M8 Red and Black DC Input Terminals—M8 Red and Black DC Input TerminalsM8 Red and Black DC Input Terminals
Output Voltage—230V Australian Standard—230V Australian Standard230V Australian Standard
Continuous Power—2000W—2000W2500W
Surge Power—4000W—4000W5000W
Output Frequency—50Hz +/-0.2%—50Hz +/-0.2%50Hz +/-0.2%
Output Receptacle—2 × Australian Std 3 pin sockets—2 × Australian Std 3 pin sockets2 × Australian Std 3 pin sockets
DC Under Voltage Protection—10V +/-0.5VDC—10V +/-0.5VDC10V +/-0.5VDC
DC Over Voltage Protection—15V +/-0.5VDC—15V +/-0.5VDC15V +/-0.5VDC
Overload—CPU controlled auto shutdown—CPU controlled auto shutdownCPU controlled auto shutdown
DC Polarity Reverse—Fuse Protection—Fuse ProtectionFuse Protection
Short Circuit / Over Heat—CPU controlled auto shutdown—CPU controlled auto shutdownCPU controlled auto shutdown
Audible Alarm—Input DC under/over voltage, fault, over current, over temperature—Input DC under/over voltage, fault, over current, over temperatureInput DC under/over voltage, fault, over current, over temperature
Cooling—Twin intelligent brushless cooling fans—Twin intelligent brushless cooling fansTwin intelligent brushless cooling fans
Indicator—Green LED (normal) / Red LED (fault/protection)—Green LED (normal) / Red LED (fault/protection)Green LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch Panel—LCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch—LCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switchLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)—200—200200
Cable Size B&S — up to 2m—0—000
Cable Size B&S — 2–4m—00—00000
Case—High Quality Anodized Aluminium (Black)—High Quality Anodized Aluminium (Black)High Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)—395 × 220 × 92—395 × 220 × 92470 × 220 × 92
Weight (kg)—4.6 (inc. remote)—4.6 (inc. remote)5.4 (inc. remote)
RedArc Alpha BCDC Charger (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
Notes* For best cell longevity. # Independently laboratory tested with 0.25C discharge rate and 0.25C charge rate up to 5000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show a residual capacity in excess of 85% of nameplate C5 capacity after 3200 cycles. In real-world conditions, the user will experience a range of temperature, current, and voltage conditions which may affect the actual performance of the battery over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.
SKUAS-GRID200
System Overview
Battery200Ah AllSpark BT ABS Lithium (AS-20012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
Inverter—
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. InverterN/A
Weight — Base Unit26.5kg
Weight — Inc. InverterN/A
Battery Level Specifications
Capacity (C5)200Ah
Watt Hours2,560Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)100A
Recommended Charge*50–80A
Charge ProfileCC/CV
Max Inverter Size2500W
Max Continuous Discharge200A
Peak Discharge (10s)500A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)21
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 200Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)220
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
SKUAS-GRID200INV
System Overview
Battery200Ah AllSpark BT ABS Lithium (AS-20012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
InverterAllSpark 12V 2000W Pro-Series
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. Inverter540 × 220 × 383mm
Weight — Base Unit26.5kg
Weight — Inc. Inverter31.1kg
Battery Level Specifications
Capacity (C5)200Ah
Watt Hours2,560Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)100A
Recommended Charge*50–80A
Charge ProfileCC/CV
Max Inverter Size2500W
Max Continuous Discharge200A
Peak Discharge (10s)500A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)21
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 200Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)220
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
AllSpark 12V 2000W Pro-Series Inverter
Model12V 2000W
Input Voltage12V
Input Voltage Range9.6–15VDC
Idle Current0.8A
Efficiency>90%
Input ConnectorM8 Red and Black DC Input Terminals
Output Voltage230V Australian Standard
Continuous Power2000W
Surge Power4000W
Output Frequency50Hz +/-0.2%
Output Receptacle2 × Australian Std 3 pin sockets
DC Under Voltage Protection10V +/-0.5VDC
DC Over Voltage Protection15V +/-0.5VDC
OverloadCPU controlled auto shutdown
DC Polarity ReverseFuse Protection
Short Circuit / Over HeatCPU controlled auto shutdown
Audible AlarmInput DC under/over voltage, fault, over current, over temperature
CoolingTwin intelligent brushless cooling fans
IndicatorGreen LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch PanelLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)200
Cable Size B&S — up to 2m0
Cable Size B&S — 2–4m00
CaseHigh Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)395 × 220 × 92
Weight (kg)4.6 (inc. remote)
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
SKUAS-GRID300
System Overview
Battery300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
Inverter—
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. InverterN/A
Weight — Base Unit33.9kg
Weight — Inc. InverterN/A
Battery Level Specifications
Capacity (C5)300Ah
Watt Hours3,840Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)200A
Recommended Charge*50–150A
Charge ProfileCC/CV
Max Inverter Size3000W
Max Continuous Discharge300A
Peak Discharge (10s)600A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)31
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)330
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
SKUAS-GRID300INV
System Overview
Battery300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
InverterAllSpark 12V 2000W Pro-Series
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. Inverter540 × 220 × 383mm
Weight — Base Unit33.9kg
Weight — Inc. Inverter35.7kg
Battery Level Specifications
Capacity (C5)300Ah
Watt Hours3,840Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)200A
Recommended Charge*50–150A
Charge ProfileCC/CV
Max Inverter Size3000W
Max Continuous Discharge300A
Peak Discharge (10s)600A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)31
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)330
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
AllSpark 12V 2000W Pro-Series Inverter
Model12V 2000W
Input Voltage12V
Input Voltage Range9.6–15VDC
Idle Current0.8A
Efficiency>90%
Input ConnectorM8 Red and Black DC Input Terminals
Output Voltage230V Australian Standard
Continuous Power2000W
Surge Power4000W
Output Frequency50Hz +/-0.2%
Output Receptacle2 × Australian Std 3 pin sockets
DC Under Voltage Protection10V +/-0.5VDC
DC Over Voltage Protection15V +/-0.5VDC
OverloadCPU controlled auto shutdown
DC Polarity ReverseFuse Protection
Short Circuit / Over HeatCPU controlled auto shutdown
Audible AlarmInput DC under/over voltage, fault, over current, over temperature
CoolingTwin intelligent brushless cooling fans
IndicatorGreen LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch PanelLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)200
Cable Size B&S — up to 2m0
Cable Size B&S — 2–4m00
CaseHigh Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)395 × 220 × 92
Weight (kg)4.6 (inc. remote)
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
SKUAS-GRID300INV2500
System Overview
Battery300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
InverterAllSpark 12V 2500W Pro-Series
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. Inverter540 × 220 × 383mm
Weight — Base Unit33.9kg
Weight — Inc. Inverter36.5kg
Battery Level Specifications
Capacity (C5)300Ah
Watt Hours3,840Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)200A
Recommended Charge*50–150A
Charge ProfileCC/CV
Max Inverter Size3000W
Max Continuous Discharge300A
Peak Discharge (10s)600A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)31
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)330
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
AllSpark 12V 2500W Pro-Series Inverter
Model12V 2500W
Input Voltage12V
Input Voltage Range9.6–15VDC
Idle Current0.8A
Efficiency>90%
Input ConnectorM8 Red and Black DC Input Terminals
Output Voltage230V Australian Standard
Continuous Power2500W
Surge Power5000W
Output Frequency50Hz +/-0.2%
Output Receptacle2 × Australian Std 3 pin sockets
DC Under Voltage Protection10V +/-0.5VDC
DC Over Voltage Protection15V +/-0.5VDC
OverloadCPU controlled auto shutdown
DC Polarity ReverseFuse Protection
Short Circuit / Over HeatCPU controlled auto shutdown
Audible AlarmInput DC under/over voltage, fault, over current, over temperature
CoolingTwin intelligent brushless cooling fans
IndicatorGreen LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch PanelLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)200
Cable Size B&S — up to 2m00
Cable Size B&S — 2–4m000
CaseHigh Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)470 × 220 × 92
Weight (kg)5.4 (inc. remote)
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
Notes* For best cell longevity. # Independently laboratory tested with 0.25C discharge rate and 0.25C charge rate up to 5000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show a residual capacity in excess of 85% of nameplate C5 capacity after 3200 cycles. In real-world conditions, the user will experience a range of temperature, current, and voltage conditions which may affect the actual performance of the battery over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.
SKUAS-GRID200AS-GRID200INVAS-GRID300AS-GRID300INVAS-GRID300INV2500
The Grid — System Overview
Battery200Ah AllSpark BT ABS Lithium (AS-20012LIABSBT)300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
Inverter—AllSpark 12V 2000W Pro-Series—AllSpark 12V 2000W Pro-SeriesAllSpark 12V 2500W Pro-Series
Dimensions — Base Unit (L×W×H mm)540 × 207 × 287
Dimensions — Inc. Inverter (L×W×H mm)N/A540 × 220 × 383N/A540 × 220 × 383540 × 220 × 383
Weight — Base Unit (kg)26.533.9
Weight — Inc. Inverter (kg)N/A31.1N/A35.736.5
AllSpark ABS Lithium Battery — Battery Level Specifications
Capacity Amp Hours (C5)200300
Watt Hours2,5603,840
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge Current (1C) for 30 mins200300
Recommended Charge Current (A)*50–8050–150
Charge ProfileCC/CV
Max Inverter Size (W — per single battery)25003000
Max Continuous Discharge (A)200300
Peak Discharge — 10 secs (A)500600
Charge Cycles @ 80% DoD# (≥85% residual capacity)
@ 60% DoD
@ 40% DoD
> 3200+#
> 4200+
> 5000+
Optimum Temperature During Charging (˚C)< 45
Operating Temperature Range (˚C)−20 to +60
Storage Temperature Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles (L×W×H mm)367 × 190 × 247 (+5mm for terminals)
Case Footprint Dimensions (L×W×H mm)340 × 183 × 247
Case MaterialABS Plastic
Weight (kg)2131
AllSpark ABS Lithium Battery — Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 200Ah3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell Over Discharge LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
Over Charge Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)220330
Over Current Detection Delay (1) (Secs)10
Over Current Detection (2) (A)500
Over Current Detection Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
Short Circuit Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET Protection)≤20mΩ
AllSpark 12V Pro-Series Inverter (2000W / 2500W)
Model—12V 2000W—12V 2000W12V 2500W
Input Voltage—12V—12V12V
Input Voltage Range—9.6–15VDC—9.6–15VDC9.6–15VDC
Idle Current—0.8A—0.8A0.8A
Efficiency—>90%—>90%>90%
Input Connector—M8 Red and Black DC Input Terminals—M8 Red and Black DC Input TerminalsM8 Red and Black DC Input Terminals
Output Voltage—230V Australian Standard—230V Australian Standard230V Australian Standard
Continuous Power—2000W—2000W2500W
Surge Power—4000W—4000W5000W
Output Frequency—50Hz +/-0.2%—50Hz +/-0.2%50Hz +/-0.2%
Output Receptacle—2 × Australian Std 3 pin sockets—2 × Australian Std 3 pin sockets2 × Australian Std 3 pin sockets
DC Under Voltage Protection—10V +/-0.5VDC—10V +/-0.5VDC10V +/-0.5VDC
DC Over Voltage Protection—15V +/-0.5VDC—15V +/-0.5VDC15V +/-0.5VDC
Overload—CPU controlled auto shutdown—CPU controlled auto shutdownCPU controlled auto shutdown
DC Polarity Reverse—Fuse Protection—Fuse ProtectionFuse Protection
Short Circuit / Over Heat—CPU controlled auto shutdown—CPU controlled auto shutdownCPU controlled auto shutdown
Audible Alarm—Input DC under/over voltage, fault, over current, over temperature—Input DC under/over voltage, fault, over current, over temperatureInput DC under/over voltage, fault, over current, over temperature
Cooling—Twin intelligent brushless cooling fans—Twin intelligent brushless cooling fansTwin intelligent brushless cooling fans
Indicator—Green LED (normal) / Red LED (fault/protection)—Green LED (normal) / Red LED (fault/protection)Green LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch Panel—LCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch—LCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switchLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)—200—200200
Cable Size B&S — up to 2m—0—000
Cable Size B&S — 2–4m—00—00000
Case—High Quality Anodized Aluminium (Black)—High Quality Anodized Aluminium (Black)High Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)—395 × 220 × 92—395 × 220 × 92470 × 220 × 92
Weight (kg)—4.6 (inc. remote)—4.6 (inc. remote)5.4 (inc. remote)
RedArc Alpha BCDC Charger (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
Notes* For best cell longevity. # Independently laboratory tested with 0.25C discharge rate and 0.25C charge rate up to 5000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show a residual capacity in excess of 85% of nameplate C5 capacity after 3200 cycles. In real-world conditions, the user will experience a range of temperature, current, and voltage conditions which may affect the actual performance of the battery over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.
SKUAS-GRID300INV2500
System Overview
Battery300Ah AllSpark BT ABS Lithium (AS-30012LIABSBT)
Battery ChargerRedArc Alpha 50 (BCDC12050B)
InverterAllSpark 12V 2500W Pro-Series
Dimensions — Base Unit540 × 207 × 287mm
Dimensions — Inc. Inverter540 × 220 × 383mm
Weight — Base Unit33.9kg
Weight — Inc. Inverter36.5kg
Battery Level Specifications
Capacity (C5)300Ah
Watt Hours3,840Wh
Rated Voltage (V)12.8
Max Charge Voltage (V)14.6
Recommended Float Voltage (V)13.6
Low Voltage Cutoff (V)10
Rapid Charge (1C/30min)200A
Recommended Charge*50–150A
Charge ProfileCC/CV
Max Inverter Size3000W
Max Continuous Discharge300A
Peak Discharge (10s)600A
Cycles @ 80% DoD#> 3200+
Cycles @ 60% DoD> 4200+
Cycles @ 40% DoD> 5000+
Optimum Charge Temp (˚C)< 45
Operating Temp Range (˚C)−20 to +60
Storage Temp Range (˚C)−40 to +125
Max Series Voltage (V)24
Max Batteries in ParallelUnlimited
Overall Dimensions incl. Handles367 × 190 × 247mm (+5mm terminals)
Case Footprint340 × 183 × 247mm
Case MaterialABS Plastic
Weight (kg)31
IP RatingIP65
Cell Level Specification
Cell TypePrismatic
Cell Connection4S1P
Cell Capacity3.2V @ 300Ah
Cell CasingNickel Plated Steel
Cell Balancing Target3.65 +/- 0.025
Cell Balance Current (mA)35 +/- 5
Cell OD LV Protection (V)2.5 +/- 0.025V
Over Discharge ReleaseApply Charge 10.5V+ & 1A+
Over Charge Cutoff (V)3.75 +/- 0.025
OC Detection Delay (Secs)1–1.6
Over Charge Release (V)3.6 +/- 0.0625V
Over Charge ReleaseAuto below Release Voltage
Over Current Detection (1) (A)330
OCD Delay (1) (Secs)10
Over Current Detection (2) (A)500
OCD Delay (2) (Secs)5
Over Current ReleaseRemove Load — Auto Release
Short Circuit ProtectionExternal Short
SC Detection Delay (µS)200–400
Short Circuit RecoveryRemove Load — Auto Release
Internal Resistance (MOSFET)≤20mΩ
AllSpark 12V 2500W Pro-Series Inverter
Model12V 2500W
Input Voltage12V
Input Voltage Range9.6–15VDC
Idle Current0.8A
Efficiency>90%
Input ConnectorM8 Red and Black DC Input Terminals
Output Voltage230V Australian Standard
Continuous Power2500W
Surge Power5000W
Output Frequency50Hz +/-0.2%
Output Receptacle2 × Australian Std 3 pin sockets
DC Under Voltage Protection10V +/-0.5VDC
DC Over Voltage Protection15V +/-0.5VDC
OverloadCPU controlled auto shutdown
DC Polarity ReverseFuse Protection
Short Circuit / Over HeatCPU controlled auto shutdown
Audible AlarmInput DC under/over voltage, fault, over current, over temperature
CoolingTwin intelligent brushless cooling fans
IndicatorGreen LED (normal) / Red LED (fault/protection)
LCD Display / Remote Switch PanelLCD Display AC Output & DC Input Voltages, Error/Fault Codes, on/off switch
Circuit Breaker (A)200
Cable Size B&S — up to 2m00
Cable Size B&S — 2–4m000
CaseHigh Quality Anodized Aluminium (Black)
Dimensions (L×W×H mm)470 × 220 × 92
Weight (kg)5.4 (inc. remote)
RedArc Alpha BCDC (BCDC12050B)
Installation LocationExternal / Under Bonnet
Battery ChemistryAGM, Gel, Calcium, Standard Lead Acid, Heated Lithium, Standard Lithium
Nominal Current Rating (A)50
Solar Input Voltage9–48V
Operating Temperature−40˚C to 85˚C
Weight (kg)0.96
Dimensions (L×W×D mm)146 × 164 × 44
Warranty2 Years
Connector TypeBare Wire
Nominal Output Voltage (VDC)12
Input Fuse Rating — not supplied (A)60
Output Fuse Rating — not supplied (A)60
Notes* For best cell longevity. # Independently laboratory tested with 0.25C discharge rate and 0.25C charge rate up to 5000 cycles at a controlled temperature of 25°C. Electronic logs recorded during testing show a residual capacity in excess of 85% of nameplate C5 capacity after 3200 cycles. In real-world conditions, the user will experience a range of temperature, current, and voltage conditions which may affect the actual performance of the battery over its life. Lower depths of discharge and high continuous charge/discharge rates will reduce overall cycle life.

FAQS

Q: I have received my Grid, how do I turn it on and connect the Bluetooth?

A: Download the AllSpark App (see the Downloads section in your battery's listing, or enter "AllSpark" into the Google Play Store or the Apple App Store), then ensure your "location services" and bluetooth is turned on. You will see your battery appear in the list under "Bluetooth" - click on here, this will take you to the Dashboard screen. Scroll to the bottom and turn the Charge Switch and Discharge Switch on as required.

 

Q: How do I store my Grid when not in use?

A: If you plan to have your Grid in storage for extended periods of time, disconnect/isolate any loads or parasitic power consumers. Charge/Discharge battery to 80% State of Charge. Battery can then be stored for up to 12 months. If storing for longer, re-charge to 80% SoC every 6-12 months.

 

Q: What is Current In/Out Net Value?

A: The Net Value is all the charge sources minus all the loads

 

Q: What do I do if my Grid goes flat?

A: If you discharge the battery in your Grid to 10.0V, it will go into Low voltage protection mode. This will disconnect all loads and the battery voltage will show as 0V. When in LV protection, the BMS disconnects power to the battery terminals. To release it from protection, open up the app and turn the BMS back on. It will then be able to take charge.

 

Q: Can I use my Grid to charge my start battery if it goes flat?

A: The RedArc Alpha 50 has a battery recharge function that allows you to recover your flat start battery with the push of a button (inside the app). It also has the ability to direct excess solar to your start battery once the Grid battery is full.

 

Q: How do I charge The Grid with a 240V ACDC battery charger?

A: Set the charger to its lithium (LiFePO4) charging profile, then connect it one of two ways:

1. Plug it into one of The Grid's 50A Anderson plugs.

2. Clip it onto the inverter posts with alligator clips (red to positive, black to negative). Make sure the clips are firmly attached so they can't slip off and touch the case.

Reviews

PRODUCTS YOU MIGHT LIKE